Cracks in walls at the expansion joint

May 12, 2023

Grieta muro - Cracks in Walls: Expansion Joint or Settlement?

  How to tell a crack at an expansion joint from one caused by differential settlement. 

              Sometimes homeowners or presidents of homeowners’ associations raise the  alarm  and ask us to check  on site a very dangerous crack that has opened up in the wall or façade of the building.  When  we  arrive,  we see that it is an expansion joint in the wall.

                An expansion joint is not usually a  problem; it is precisely the construction solution that allows the floor or the ceiling slab,  or the partition walls,   to have  room to expand,  so that the surrounding areas do not crack or lift.

                 It is worth knowing that all  building materials undergo contraction and expansion as a result of the moisture and temperature to which they are exposed. Expansion joints are the construction  solutions that allow  these movements to take place.

              Expansion joints are built into all the construction elements of the building (structure, floors, walls, façades, roofs and ceilings) and  are necessary in any building or building material, also because of seismic or thermal effects, as the building is subject  to contraction and expansion.

              It is important to apply the spacing between expansion joints set by the regulations for each case. Otherwise, problems may arise.

             The Technical Building Code requires expansion joints to be installed in buildings, so that there are no continuous elements more than 40 m long.            

             To create these joints, double  columns can also  be built with a gap of approximately 5 centimetres between them, creating independent structural elements.

              Sometimes,  to avoid these double-column structures – which complicate the layout of garages or homes – stainless steel structural dowels are installed  to transmit these loads.

              In short, a crack at an expansion joint has nothing to do with a crack caused by differential settlement, although the former can also cause problems. They may appear to have the same origin, but they are completely different. A crack that appears in a zig-zag pattern, even if it is narrower or finer than one at an expansion joint, is potentially more dangerous. That diagonal, stepped crack appearing on the façade, through which light sometimes passes, and whose perpendicular points to a serious problem that has occurred in the foundations. The buried foundations, which should lie on a single plane, have given way in one part as a result of a failure in the ground.

                This differential settlement can be explained with the example of a chair. A chair is made to bear weight and be supported at four points (or legs). If we pull one leg off the chair, or  it fails, since the chair is not designed for three legs, the remaining legs are forced at an angle, the chair becomes unbalanced, and it will probably break and the person sitting on it will fall spectacularly.

                 The same happens with foundations:  if in one part – let us imagine – a corner of the foundations fails, because it is defective, or because it sinks further as  that  part of the ground is softer than the rest, or because the ground becomes flooded and had not been compacted beforehand, part of the ground is washed away and the footing supporting the foundations is left unsupported; the foundations are pulled downwards and the building may collapse. That is differential settlement, for which the architect bears full  responsibility for preventing it, and which of course has nothing to do with an expansion joint. Most of the fault-based liability of architects arises from differential settlement caused by failures in the  foundations.     

              If your building has a vertical crack in the wall or façade and you want to find out  whether it is a crack at an expansion joint or a crack caused by structural problems, contact our technical department.

0 Comments

Submit a Comment

Your email address will not be published. Required fields are marked *

Responsable » DPCON RECLAMACIONES JUDICIALES SL
Finalidad » Prestación de servicios requeridos
Legitimación » tu consentimiento
Destinatarios » No se cederán datos a terceros.
Derechos » Tiene derecho de acceso, rectificación y supresión

Related articles

Claiming for Cracks in Your Home: These Are Your Options

Claiming for Cracks in Your Home: These Are Your Options

A crack in the living-room wall, a diagonal hairline crack next to a door that no longer closes properly, or a façade that is starting to open up. Sound familiar? In many homes they are part of the building and, naturally, the first reaction is usually concern,...

Is it worth taking action over latent defects?

Is it worth taking action over latent defects?

This scenario is more common than we think: we move into a new home that has cost us many years of savings and, within a few months, the first cracks in a partition wall appear, a damp patch shows up on the bedroom ceiling or the living room floor starts to lift. In...

DON’T HESITATE TO CONSULT US!

CUSTOM BUDGETS

14 + 9 =

GDPR-LSSI

The information you submit will be added to a file owned by DPCON RECLAMACIONES JUDICIALES S.L. It will be used solely to process your data and handle your request, in compliance with Regulation (EU) 2016/679 (GDPR), Organic Law 3/2018 (LOPDGDD) and Royal Decree 1720/2007. Your data will not be shared with third parties except when legally required, and will be retained until you request deletion.
You may exercise your rights of access, rectification, erasure, portability, restriction, objection and withdrawal of consent at any time by writing to dpcon@dpcon.es.

Contact

Telephones: 911 61 01 65 / 646 567 732

Email: dpcon@dpcon.es

Headquarters: Paseo de la Castellana 257, 1º Sur
CP 28046, Madrid

SERVICE ALL OVER SPAIN

WhatsApp