Prevencion incendios seguridad - Fire Prevention in Buildings: What the Rules Require

Buildings must be properly protected against fire

At present, the regulations setting out all the requirements that buildings must meet to be properly protected against fire are those of the Technical Building Code (CTE), specifically in the Basic Document SI “Safety in the event of Fire”.


Buildings must have fire protection equipment and installations. Materials must be fire-resistant. Extinguishers, fire hose reels, etc. must be properly signposted. Signs must be photoluminescent.


The aim of this basic “Safety in the event of fire” standard is to reduce to acceptable limits the risk of users of a building suffering harm from an accidental fire, as a result of the characteristics of its design, construction, use and maintenance. To meet this aim, buildings shall be designed, built, maintained and used in such a way that, in the event of fire, the basic requirements are met.

For this reason, all buildings must have fire protection equipment and installations such as portable extinguishers, fire hose reels, firefighting lifts, external hydrants or automatic extinguishing systems.

Likewise, the design, installation, commissioning and maintenance of all installations, materials and equipment must comply with the provisions of the “Regulation on Fire Protection Installations”.

One of the requirements that properties must meet is, for example, that buildings must be divided into fire compartments, each with a maximum permitted area. Any area whose intended use is different from and ancillary to the main use of the building or establishment of which it forms part must constitute a separate fire compartment.

In addition, the materials used in construction must have a specified fire resistance, as must the walls, ceilings and doors bounding fire compartments.

As regards the signposting of all fire protection equipment, point 2 of DB SI4 states that extinguishers, fire hose reels, external hydrants, manual call points and triggering devices for extinguishing systems must be signposted with signs measuring 210 x 210 mm where the viewing distance does not exceed 10 m, with signs measuring 420×420 mm where the viewing distance is between 10 and 20 m, and with signs measuring 594×594 mm where the distance is 20 to 30 metres. It is also essential that all signs are photoluminescent, since this is the only way to ensure they are visible when there is not enough natural light or when the general lighting supply fails.

0 Comments

Submit a Comment

Your email address will not be published. Required fields are marked *

Responsable » DPCON RECLAMACIONES JUDICIALES SL
Finalidad » Prestación de servicios requeridos
Legitimación » tu consentimiento
Destinatarios » No se cederán datos a terceros.
Derechos » Tiene derecho de acceso, rectificación y supresión

Related articles

DON’T HESITATE TO CONSULT US!

CUSTOM BUDGETS

10 + 15 =

GDPR-LSSI

The information you submit will be added to a file owned by DPCON RECLAMACIONES JUDICIALES S.L. It will be used solely to process your data and handle your request, in compliance with Regulation (EU) 2016/679 (GDPR), Organic Law 3/2018 (LOPDGDD) and Royal Decree 1720/2007. Your data will not be shared with third parties except when legally required, and will be retained until you request deletion.
You may exercise your rights of access, rectification, erasure, portability, restriction, objection and withdrawal of consent at any time by writing to dpcon@dpcon.es.

Contact

Telephones: 911 61 01 65 / 646 567 732

Email: dpcon@dpcon.es

Headquarters: Paseo de la Castellana 257, 1º Sur
CP 28046, Madrid

SERVICE ALL OVER SPAIN

WhatsApp